Case Study: The King’s School Science Learning Centre, Sydney Australia

By Alistair Grice, mySmartCTI. Founded in 1831, The King’s School is Australia’s oldest and one of its most prestigious independent schools. Located on 148 hectares in the Sydney suburb of North Parramatta, The King’s School is home to around 1500 students, from kindergarten to Year 12. Construction started on the AUS$20M Science Learning Centre in […]

Altenburger Electronic Offers Programmable KNX-Switch-Dim-Actuator

The Altenburger Electronic Programmable KNX-Switch-Dim-Actuator has integrated scene memory for up to 25 scenes with pre-selectable fade time for each scene (1 – 9999 sec.) with 0-10V/1-10V-interface. Features • for the realization of convenience lighting controls in combination with pushbutton panels, touch panels, visualizations, layout-tableaus, etc. • for switching, dimming, cross-fading and entering of light […]

Warema Presents its climatronic KNX Weather Central Control System at ISH 2015

Solutions from Warema represent a responsible and economic approach to using energy resources From 10 to 14 March 2015, Warema will present its newly available OptiControl room automation solution and the new Warema climatronic® KNX weather central control system at the KNX Association group booth A49 in Hall 10.3. Both solutions are ideally suited for […]

How to Solve it: Different Ways of Controlling KNX Dimmer Modules

By Ben Lewis, KNX Consultants. There can be confusion when it comes to figuring out the best way to design the operation of lighting control dimmers. The flexibility of KNX means that there are several ways that it can be implemented, and the standardisation ensures that all manufacturers offer at least the same basic set […]

Case Study: ABB’s New HQ in France Saves 25% in Energy Costs

By Edouard Vidoudez, ABB France. The new ABB headquarters in France is located outside Paris in Cergy Pontoise. It was converted from a factory into an office building, and is now fully equipped with advanced building automation systems including centralised monitoring. To bring the site into line with safety standards, ABB took the opportunity to […]

Case Study: KNX installation for Hotel in Jönköping, Sweden

By Giangiacomo Pastore, Eelectron. The Vox Hotel in Jönköping, Sweden is a new hotel where a high level of automation is matched by beautiful environments, high-end finishes, and a green attitude. The hotel looks out onto Lake Vättern, and boasts 143 premium rooms as well as communal areas. The owner had high ambitions for the […]

Elsner Elektronik Introduces Sewi KNX Indoor Monitor

The Sewi KNX indoor sensor monitors not only the presence of persons and the brightness, e.g. to switch light in an energy-optimized way, but also measures temperature, air humidity and CO2 for ambient climate control. The sensor is mounted on the ceiling or wall and is available in different variants as single or combined unit. […]

Case Study: KNX-based Fire Station in Bergen op Zoom, The Netherlands

By Remco Hoveling, BAM Techniek What could be a greater contrast than water and fire? For the fire department in Bergen op Zoom, both are equally important and have been incorporated in a special architectural design. Built on the exact spot where the former city wall held back the sea water, the new fire department […]

B.E.G. Offers Almost Invisible PD11-KNX-FLAT Occupancy Detector

The design-oriented PD11-KNX-FLAT occupancy detector for ceiling installation is almost invisible, with a surface height of only 0.85mm. Its innovative construction helps it to blend in unobtrusively with any interior decor. It extends the KNX detector family by providing a discreet solution for monitoring areas up to 9m in diameter. This occupancy detector is the […]

Case Study: Providing a KNX Infrastructure within a Listed Building – Part 3

By Ben Lewis, KNX Consultants. In this three-part series, we have been covering a KNX installation in our headquarters based in a 17th-century Grade II listed former dovecote, located in Staunton, Gloucestershire, UK. Whilst this has been implemented within a relatively small office, the key message is that this type of installation can be applied […]